278 research outputs found

    The FLASHForward Facility at DESY

    Get PDF
    The FLASHForward project at DESY is a pioneering plasma-wakefield acceleration experiment that aims to produce, in a few centimetres of ionised hydrogen, beams with energy of order GeV that are of quality sufficient to be used in a free-electron laser. The plasma wave will be driven by high-current density electron beams from the FLASH linear accelerator and will explore both external and internal witness-beam injection techniques. The plasma is created by ionising a gas in a gas cell with a multi-TW laser system, which can also be used to provide optical diagnostics of the plasma and electron beams due to the <30 fs synchronisation between the laser and the driving electron beam. The operation parameters of the experiment are discussed, as well as the scientific program.Comment: 19 pages, 9 figure

    Energy-Spread Preservation and High Efficiency in a Plasma-Wakefield Accelerator

    Get PDF
    Energy-efficient plasma-wakefield acceleration of particle bunches with low energy spread is a promising path to realizing compact free-electron lasers and particle colliders. High efficiency and low energy spread can be achieved simultaneously by strong beam loading of plasma wakefields when accelerating bunches with carefully tailored current profiles [M. Tzoufras et al., Phys. Rev. Lett. 101, 145002 (2008)PRLTAO0031-900710.1103/PhysRevLett.101.145002]. We experimentally demonstrate such optimal beam loading in a nonlinear electron-driven plasma accelerator. Bunches with an initial energy of 1 GeV were accelerated by 45 MeV with an energy-transfer efficiency of (42±4)% at a gradient of 1.3  GV/m while preserving per-mille energy spreads with full charge coupling, demonstrating wakefield flattening at the few-percent level

    Tunable and precise two-bunch generation at FLASHForward

    Full text link
    Beam-driven plasma-wakefield acceleration based on external injection has the potential to significantly reduce the size of future accelerators. Stability and quality of the acceleration process substantially depends on the incoming bunch parameters. Precise control of the current profile is essential for optimising energy-transfer efficiency and preserving energy spread. At the FLASHForward facility, driver--witness bunch pairs of adjustable bunch length and separation are generated by a set of collimators in a dispersive section, which enables fs-level control of the longitudinal bunch profile. The design of the collimator apparatus and its commissioning is presented.Comment: 7 pages, 5 figures, to be published in the proceedings of the 4th European Advanced Accelerator Concepts Workshop, 15-21 September 2019, La Biodola Bay, Isola d'Elba, Ital

    Measurement of neutral current e+/-p cross sections at high Bjorken x with the ZEUS detector

    Get PDF
    The neutral current e+/-p cross section has been measured up to values of Bjorken x of approximately 1 with the ZEUS detector at HERA using an integrated luminosity of 187 inv. pb of e-p and 142 inv. pb of e+p collisions at sqrt(s) = 318GeV. Differential cross sections in x and Q2, the exchanged boson virtuality, are presented for Q2 geq 725GeV2. An improved reconstruction method and greatly increased amount of data allows a finer binning in the high-x region of the neutral current cross section and leads to a measurement with much improved precision compared to a similar earlier analysis. The measurements are compared to Standard Model expectations based on a variety of recent parton distribution functions.Comment: 39 pages, 9 figure

    Infrastructure for Detector Research and Development towards the International Linear Collider

    Full text link
    The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.Comment: 54 pages, 48 picture

    Measurement of the cross-section ratio sigma_{psi(2S)}/sigma_{J/psi(1S)} in deep inelastic exclusive ep scattering at HERA

    Get PDF
    The exclusive deep inelastic electroproduction of ψ(2S)\psi(2S) and J/ψ(1S)J/\psi(1S) at an epep centre-of-mass energy of 317 GeV has been studied with the ZEUS detector at HERA in the kinematic range 2<Q2<802 < Q^2 < 80 GeV2^2, 30<W<21030 < W < 210 GeV and t<1|t| < 1 GeV2^2, where Q2Q^2 is the photon virtuality, WW is the photon-proton centre-of-mass energy and tt is the squared four-momentum transfer at the proton vertex. The data for 2<Q2<52 < Q^2 < 5 GeV2^2 were taken in the HERA I running period and correspond to an integrated luminosity of 114 pb1^{-1}. The data for 5<Q2<805 < Q^2 < 80 GeV2^2 are from both HERA I and HERA II periods and correspond to an integrated luminosity of 468 pb1^{-1}. The decay modes analysed were μ+μ\mu^+\mu^- and J/ψ(1S)π+πJ/\psi(1S) \,\pi^+\pi^- for the ψ(2S)\psi(2S) and μ+μ\mu^+\mu^- for the J/ψ(1S)J/\psi(1S). The cross-section ratio σψ(2S)/σJ/ψ(1S)\sigma_{\psi(2S)}/\sigma_{J/\psi(1S)} has been measured as a function of Q2,WQ^2, W and tt. The results are compared to predictions of QCD-inspired models of exclusive vector-meson production.Comment: 24 pages, 8 figure

    Eupraxia, a step toward a plasma-wakefield based accelerator with high beam quality

    Get PDF
    The EuPRAXIA project aims at designing the world's first accelerator based on advanced plasma-wakefield techniques to deliver 5 GeV electron beams that simultaneously have high charge, low emittance and low energy spread, which are required for applications by future user communities. Meeting this challenging objective will only be possible through dedicated effort. Many injection/acceleration schemes and techniques have been explored by means of thorough simulations in more than ten European research institutes. This enables selection of the most appropriate methods for solving each particular problem. The specific challenge of generating, extracting and transporting high charge beams, while maintaining the high quality needed for user applications, are being tackled using innovative approaches. This article highlights preliminary results obtained by the EuPRAXIA collaboration, which also exhibit the required laser and plasma parameters

    Improved functionalization of oleic acid-coated iron oxide nanoparticles for biomedical applications

    Get PDF
    Superparamagnetic iron oxide nanoparticles can providemultiple benefits for biomedical applications in aqueous environments such asmagnetic separation or magnetic resonance imaging. To increase the colloidal stability and allow subsequent reactions, the introduction of hydrophilic functional groups onto the particles’ surface is essential. During this process, the original coating is exchanged by preferably covalently bonded ligands such as trialkoxysilanes. The duration of the silane exchange reaction, which commonly takes more than 24 h, is an important drawback for this approach. In this paper, we present a novel method, which introduces ultrasonication as an energy source to dramatically accelerate this process, resulting in high-quality waterdispersible nanoparticles around 10 nmin size. To prove the generic character, different functional groups were introduced on the surface including polyethylene glycol chains, carboxylic acid, amine, and thiol groups. Their colloidal stability in various aqueous buffer solutions as well as human plasma and serum was investigated to allow implementation in biomedical and sensing applications.status: publishe

    Horizon 2020 EuPRAXIA design study

    Get PDF
    The Horizon 2020 Project EuPRAXIA ("European Plasma Research Accelerator with eXcellence In Applications") is preparing a conceptual design report of a highly compact and cost-effective European facility with multi-GeV electron beams using plasma as the acceleration medium. The accelerator facility will be based on a laser and/or a beam driven plasma acceleration approach and will be used for photon science, high-energy physics (HEP) detector tests, and other applications such as compact X-ray sources for medical imaging or material processing. EuPRAXIA started in November 2015 and will deliver the design report in October 2019. EuPRAXIA aims to be included on the ESFRI roadmap in 2020
    corecore